MAINTENANCE PROCEDURE
INITIAL 10 HOURS MAINTENANCE (ONL
Y FOR THE FIRST 100 HOURS)
For
the
first
100
hours of operation on a new machine, press
the switch shown in the figure every 10 hours to actuate the
manual greasing.
INITIAL 250 HOURS MAINTENANCE (ONLY AFTER THE FIRST 250
HOURS)
Perform the following maintenance work only after the first 250 hours of operation on new machines.
• Replace HST oil filter cartridge
• Replace hydraulic oil filter cartridge
For details of the method of replacement or maintenance. See EVERY 1000 HOURS MAINTENANCE and EV-
ERY 2000 HOURS MAINTENANCE.
WHEN REQUIRED
METHOD FOR CHECKING, CLEANING AND REPLACING AIR CLEANER
kk
WARNING
• When using compressed air, there is a danger that dirt may scatter and cause personal injury.
Always wear protective eyeglasses, dust mask, or other protective equipment.
• When removing the outer element
from the air cleaner body, it is dangerous to pull it out by force.
When working in high places or where the foothold is poor, be careful not to fall because of the re-
action when pulling out the outer element.
MAINTENANCE MAINTENANCE PROCEDURE
4-15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu WA320-8 and is the answer not in the manual?

Komatsu WA320-8 Specifications

General IconGeneral
BrandKomatsu
ModelWA320-8
CategoryFront End Loaders
LanguageEnglish

Related product manuals