floor.
The electrical equipment near the working area must conform to GB / T standards, national
electrical codes provided on first level second-class venue, which is installed by a
corresponding qualified electrical contractor.
2-2-7 Electrical requirements
the machine equips with single-phase power, and requests a good independent grounding
cable. Grounding resistance is less than 10 Ohms.
Power supply voltage range of DC 220V (± 10%) AC 50Hz or 60Hz .The electrical power
line output must be installed by professional staff or contractors.
Circuit breaker ratings are as follows
Power\Voltage AV 220V AV 110V
Single-phase 10A/phase 20A/phase
Maximum power consumption is less than 2KW, average power consumption is 1.2 KW.
UPS can be 3KW, which can access the computer and the machine power.
The machine equips with a standard 5m cable.
2-2-8 Operator requirements
For machines operators, following requirements and responsibilities are needed:
Responsible for operation and maintenance of machine
Keep connection with Printer technical support service
Able to solve problems and maintenance through telephone
Experience with Windows and PC
The electronic and mechanical technical background
Capacity of color theory, knowledge of front and post-production printing.
2-2-9 Requirements of installation
Installation requires that equipment must be installed in a horizontal place. Leveling the
equipment from front to back according to the level after moving the equipment in place .
It’s good for easy maintenance and cooperation in daily operation if installing a telephone
nearby operator console.。