Basic units in the power range 0.25 ... 2.2 kW
Terminal assignment - Standard I/O E82ZAFSC
7
Extensions for automation
7.2
7.2.2
L
7.2-7
EDS82EV903-1.0-11/2002
X3/
62 Resolution: 10 bit
Linearity fault:
±0,5 %
Temperature drift (0...+60 °C): 0.3 %
Load capability I
max
=2mA
8
Resolution: 10 bit
Linearity fault:
± 0.5 %
Temperature drift: 0.3 % (0...+60°C)
Input resistance
• Voltage signal: > 50 k Ω
• Current signal: 250 Ω
9 Load capability I
max
=10mA
7 Isolated from terminal X3/39 (GND2)
20 Load capability: Σ I
max
=40mA
28
Input resistance: 3.3 kΩ
E1
1)
E2
1)
E3
1=HI
H (+12 ... +30
), PL
level, HTL
E4
=
...
,
,
39 Isolated from terminal X3/7 (GND1)
A1 Load capability:
I
max
= 10 mA, at internal supply
I
max
= 50 mA, at external supply
1)
Optional frequency input 0 ... 10 kHz single-tracked or 0 ... 1 kHz double-tracked, configuration via C0425
GND1
62 8
9
20 28
E1 E2
E3
E4
39
A1
59
X3
GND1
GND2
+5V
+20V
8
9
7
0…+5V
1k … 10k
AIN1
AOUT1
DIGOUT1
77
GND2
8
9
7
0 … +5 V
1k … 10k
GND1
62
7
8 9 20 28
E1
E2 E3 E4 39 A1 59
X3
7
GND1
+5V
+20V
+
_
24 V ext.
(+12 V DC - 0 %
...
+30VDC+0%,
max. 120 mA)
AIN1
AOUT1
DIGOUT1
E82ZAFS004 E82Zafs005
Fig. 7.2-6 Wiring at internal /external supply
internal voltage source X3/20 (+20 V DC, max. 40 mA)
external voltage source + 24 V DC (+12 V DC - 0 % ... +30 V DC + 0 % ,
max. 120 mA)
The min. wiring requirements for operation
Technical data
Wiring