Basic units in the power range 3 ... 11 kW
Terminal assignment - Standard I/O E82ZAFSC
7
Extensions for automation
7.3
7.3.2
L
7.3-4
EDS82EV903-1.0-11/2002
7.3.2 Terminal assignment - Standard I/O E82ZAFSC
)
))
) Note!
Shield control cables to avoid interferences!
1
1
2
2
3
3
4
4
5
5
62
77
8 9 20 28
E1 E2 E3 E4
39
A1
59
0
1
2
3
E82ZAFS006/AFX009
Fig. 7.3-5 Front and rear view
0
E82ZAFSC function module
1
Terminal strip X3, digital and analog inputs and outputs
2
DIP switch for configuration of the analog input 1 (AIN1) at X3/8
3
Nameplate
The device is wired using a terminal strip which is integrated into the module.
Electrical connection Terminal strip with screw connection
Possible connections
rigid: 1.5 mm
2
(AWG 16)
flexible:
without wire crimp cap
1.0 mm
2
(AWG 18)
with wire crimp cap, without plastic sleeve
0.5 mm
2
(AWG 20)
with wire crimp cap, with plastic sleeve
0.5 mm
2
(AWG 20)
Tightening torque 0.22 ... 0.25 Nm (1.9 ... 2.2 lb-in)
Bare end 5mm
Screw terminal data