8.3.3 Opmising the stalling behaviour
If the motor is driven with frequencies above the rated motor frequency, the operang point
is shied to the "eld weakening range". In this range, the motor voltage does not increase
proporonately to the output frequency anymore. As a consequence, the inverter automa-
cally reduces the maximum current since the full torque is not available anymore at these fre-
quencies.
For special motors which enable an operaon in the eld weakening range, the behaviour in
the eld weakening range can be adapted to the motor with 0x2B0C (P319.00).
DANGER!
Danger by incorrect parameterisaon.
Possible consequences: damage to material assets and injury to persons
Only change the default seng (0 Hz) in 0x2B0C (P319.00) aer consulng the motor man-
ufacturer!
Recommendaon: Maintain default seng (0 Hz).
Precondions
The funcon is only eecve in the motor control type "V/f characterisc control (VFC open
loop)".
Motor control
Opmisaon of motor control
Opmising the stalling behaviour
133

Table of Contents

Other manuals for Lenze I51AE175F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I51AE175F and is the answer not in the manual?

Lenze I51AE175F Specifications

General IconGeneral
BrandLenze
ModelI51AE175F
CategoryInverter
LanguageEnglish

Related product manuals