8.3 Error codes
Error code Descripon Classicaon Remedy
Blocking
me[s]
Reset
possible
2250
CiA: Connuous overcurrent (inside the device) Fault • Check motor and wiring for short circuit.
• Check brake resistor and wiring.
• Check motor circuit (delta connecon, star connecon).
• Check seng of the motor data.
5 Yes
2320
Short circuit or earth leakage on the motor
side
Fault • Check motor cable.
• Check the length of the motor cable.
• Use shorter or lower-capacitance motor cable.
5 Yes
2340
CiA: Short circuit (inside the device) Fault • Check motor cable for short circuit. 5 Yes
2350
CiA: i²*t overload (thermal state) Fault • Check drive sizing.
• Check machine/driven mechanics for excessive load.
• Check seng of the motor data.
• Reduce values for slip compensaon (P315.01, P315.02) and oscillaon damping (P318.01, P318.02).
5 Yes
2382
Error: Device ulisaon (Ixt) too high Fault • Check drive sizing.
• Reduce maximum overload current of the inverter (P324.00).
• In case of high mass ineras, reduce maximum overload current of the inverter (P324.00) to 150 %.
3 Yes
2383
Warning: Device ulisaon (Ixt) too high Warning • Check drive sizing. 0 Yes
3120
Mains phase fault Fault • Check wiring of the mains connecon • Check fuses. 0 Yes
3210
DC bus overvoltage Fault • Reduce dynamic performance of the load prole.
• Check mains voltage.
• Check sengs for braking energy management.
• Connect brake resistor to the power unit and acvate the integrated brake chopper. (P706.01 = 0: brake resistance).
0 Yes
3211
Warning: DC bus overvoltage Warning • Reduce dynamic performance of the load prole.
• Check mains voltage.
• Check sengs for braking energy management.
• Connect brake resistor to the power unit and acvate the integrated brake chopper. (P706.01 = 0: brake resistance).
0 Yes
3220
DC bus undervoltage Trouble • Check mains voltage.
• Check fuses.
• Check DC-bus voltage (P105.00).
• Check mains sengs.
0 Yes
3221
Warning: DC bus undervoltage Warning • Check mains voltage.
• Check fuses.
• Check DC-bus voltage.
• Check mains sengs.
0 Yes
3222
DC-bus voltage too low for switch-on Warning • Check mains voltage.
• Check fuses.
• Check mains sengs.
0 Yes
4210
PU: Overtemperature fault Fault • Check mains voltage.
• Provide for a sucient cooling of the device (display of the heatsink temperature in P117.01).
• Clean fan and venlaon slots. If required, replace fan.
• Reduce switching frequency (P305.00).
0 Yes
4281
Heatsink fan warning Warning • Clean fan and venlaon slots. If required, replace fan. The fans can be unlocked via locking hooks and can then be
removed.
0 Yes
4310
Error: Motor overtemperature Fault • Check drive sizing.
• Check motor temperature sensor and wiring (X109/T1 and X109/T2).
5 Yes