ENGLISH_index
44
Transmission/Reception Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command1]: Identifies between the factory setting and the user setting modes.
* [Command2]: Controls monitor sets.
* [Set ID]: Used for selecting a set you want to control. A unique Set ID can be assigned to each set ranging from 1
to 1000(01H~3E8H) under Settings in the OSD menu. Selecting ‘00H’ for Set ID allows the simultaneous
control of all connected monitors. (The maximum value may differ depending on the model.)
* [Data]: Transmits command data. Data count may increase depending on the command.
* [Cr]: Carriage Return. Corresponds to ‘0x0D’ in ASCII code.
* []: White Space. Corresponds to ‘0x20’ in ASCII code.
Acknowledgement
[Command2][ ][Set ID][ ][OK/NG][Data][x]
* The Product transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if
the data is FF, it indicates the present status data. If the data is in data write mode, it returns the data of the PC
computer.
* If a command is sent with Set ID ‘00’ (=0x00), the data is reflected to all monitor sets and each monitor set does not
send an acknowledgement (ACK).
* If the data value ‘FF’ is sent in control mode via RS-232C, the current setting value of a function can be checked (only
for some functions).
* Some commands are not supported depending on the model.

Table of Contents

Other manuals for LG 32SM5KB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG 32SM5KB and is the answer not in the manual?

LG 32SM5KB Specifications

General IconGeneral
BrandLG
Model32SM5KB
CategoryDigital Signage
LanguageEnglish

Related product manuals