EasyManuals Logo
Home>Manitowoc>Construction Equipment>GROVE GMK 5095

Manitowoc GROVE GMK 5095 User Manual

Manitowoc GROVE GMK 5095
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #181 background imageLoading...
Page #181 background image
Boom extension
4.2 Description of the rigging work
Lattice extension operating instructions 3 112 441 en 4 - 13
GMK 4100/4100-L/5095
11.01.2008
Main boom con-
nection – section 3
(A) – Establishing the connection
If necessary, bring the connections (2) on
the left side of the main boom head into the
position for operating with the lattice exten-
sion;
à p. 3 - 34.
Lay the short ends (1) on the left-hand side
out of section 3 and up to the main boom
head.
Remove the protective caps and connect the
short ends (1) to the connections (2).
(B) – Disconnecting the connection
Disconnect the short ends (1) from the con-
nections (2).
Close the short ends and the connections with the protective caps.
Guide the short ends (1) on the left in section 3 and lay them in front of
the lower cross-strut so that they hang out of section 3 when raising.
s