Maintenance work on the carrier
7.6 Transmission
09.03.2018
Maintenance manual 3 302 746 en 7 - 41
GMK5200-1
7.6.2 Checking the VIAB oil level
Spare parts and
tools
– Receptacle, approx. 5 l (1.5 gal); à p. 2 - 4.
– Torque wrench for torque of 25 Nm (18.4 lbf ft).
Prerequisites – The transmission oil must have an operating temperature of at least 60 °C
(140 °F)).
– The truck crane must be raised on outriggers or parked over an inspection
pit.
– The truck crane must not running and secured against unauthorised use;
à p. 2 - 3.
Checking the oil
level
• Remove the drain plug (1).
• Check the oil level; it must reach to the lower
edge of the opening.
• Fit a new gasket and tighten the drain plug.
If the oil level is too low
• Top up the oil; à p. 7 - 43.
M 12
Designation Quantity GROVE part no.
Gasket 24 x 29 Cu DIN 7603 1 00117145
S
Risk of damage to the transmission.
If the oil level is too low or too high, this can lead to malfunctions and dam-
age to the transmission.
Check the oil level at the correct intervals.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5200-1 and is the answer not in the manual?

Manitowoc Grove GMK 5200-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5200-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals