Maintenance work on the carrier
7.17 Electrical system
7 - 124 3 302 746 en Maintenance manual
GMK5200-1
09.03.2018
7.17.2 Checking the batteries
Before checking
• Switch off the battery master switch;
à Operating manual.
• Pull the battery box out.
M 1
G
Risk of poisoning from batteries containing lead .
Battery poles, terminals and parts inside the battery contain lead. Residue
containing lead can stick to your hands and may not be allowed to enter
your body – e.g. by touching food.
Wash your hands after working on batteries.
G
Risk of explosion from escaping hydrogen.
Do not place tools on the battery and keep naked lights away from it.
G
Risk of explosion from static charge.
Only use antistatic cloth to clean the batteries.
This prevents static charging which could result in hydrogen mixtures
exploding.
G
Risk of burns from battery acids.
Battery acid is highly caustic. Wear safety glasses and protective gloves. Do
not tilt the battery. Rinse off or wash out any acid spray on the skin or cloth-
ing using soap suds.
S
Risk of damage to the crane's electrical system.
Always switch off the battery master switches before commencing work on
the truck crane's electrical system.
This prevents short circuits and resulting damage to the electrical system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5200-1 and is the answer not in the manual?

Manitowoc Grove GMK 5200-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5200-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals