Maintenance work on the carrier
7.6 Transmission
09.03.2018
Maintenance manual 3 302 746 en 7 - 43
GMK5200-1
7.6.4 Changing the VIAB oil
Oil, spare parts
and tools
– Receptacle, approx. 20 l (5 gal); à p. 2 - 4.
– Torque wrench.
Prerequisites – The transmission oil must have been warmed up in advance and reached
an operating temperature of at least 60 °C (140 °F)).
– The engine must have been run at full throttle in 8th gear for 10 to
15 seconds.
– The truck crane must be raised on outriggers or parked over an inspection
pit.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Draining oil
s
Gear oil in
litres (gal)
Specification
Classification
GROVE part no.
11.0 (2.9) Shell Spirax
S6 ATF VM
04162043
Designation Quantity GROVE part no.
Gasket 24 x 29 Cu DIN 7603
(oil filler neck, top)
1 00117145
Gasket 24 x 29 Cu DIN 7603
(oil level plug, side)
1 00117145
Gasket 24 x 29 Cu DIN 7603
(oil drain cock, bottom)
1 00117145
Gasket 14 x 18 Cu DIN 7603
(heat exchanger oil drain cock)
1 00117131
Filter exchange kit 1 04163770
Vent valve filter 1 04163771
Cover gasket filter 1 04163772
G
Risk of scalding from gear oil at operating temperature.
You could burn yourself by gear oil escaping in an uncontrolled manner at
operating temperature. Wear appropriate protective gloves and take care
not to come into contact with the gear oil.