Part Number STH025 11/16 115
WATER THAW CYCLE
FIRMWARE VERSION 5.010 AND HIGHER
When the damper/curtain does not open during the
7 minute harvest cycle the following water thaw cycle
occurs:
• 7 minutes - The compressor, harvest solenoid valve
and dump valve de-energize.
The water pump remains energized and the water
inlet valve energizes until water touches the high
water level probe.
• Water is circulated, dumped and refilled to the high
water level probe 18 times (approximately 1 hour).
Model 1200 or smaller:
Circulate 165 seconds, dump 45 seconds
Model 1400 and larger
Circulate 240 seconds, dump 120 seconds
• At the end of the thaw cycle the ice machine will start
another freeze cycle (approximately 1 - 1.75 hour).
Curtain Operation In Water Assist Harvest
• Open & close damper = Continue Thaw Cycle
• Open damper 30 seconds = Full Bin Shutoff
NOTE: Use the keypad and turn the ice machine off
and then on to terminate the cycle. Disconnecting and
reconnecting power to end the cycle will result in the ice
machine restarting in a harvest cycle.