22 Part Number STH025 11/16
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not met,
select another location.
• The location must be free of airborne and other
contaminants.
• Self contained air and water cooled - The air
temperature must be at least 35°F (1.6°C), but must
not exceed 110°F (43.4°C).
• Remote air cooled - The air temperature must be at
least -20°F (-29°C), but must not exceed 120°F (49°C)
• Ice Making Water Inlet - Water Pressure must be at
least 20 psi (1.38 bar), but must not exceed 80 psi
(5.52 bar).
• Condenser Water Inlet - Water Pressure must be at
least 20 psi (1.38 bar), but must not exceed
• 150 psi (10.34 bar).
• The location must not be near heat-generating
equipment or in direct sunlight and protected from
weather.
• The location must not obstruct air flow through or
around the ice machine. Refer to chart below for
clearance requirements.
• The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty. See “Removal from Service/
Winterization”