260 Part Number STH025 11/16
I1406 SERIES
I1406A
Self-Contained Air-Cooled Model
Characteristics vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
Water Temperature °F/°C
50/10 70/21 90/32
70/21 11.0-12.6 12.1-14.0 13.2-14.6
0.75-2.0
80/27 12.4-13.3 13.3-14.7 14.3-15.2
90/32 13.2-14.6 14.0-15.5 15.1-16.9
100/38 14.0-15.5 15.2-17.1 16.6-19.3
110/43 15.6-17.3 16.5-20.0 19.3-21.4
1 Times in minutes
24 HOUR ICE PRODUCTION
Air Temp. Entering
Condenser °F/°C
Water Temperature °F/°C
12
50/10 70/21 90/32
70/21 1530 1400 1160
80/27 1450 1370 1295
90/32 1305 1235 1000
100/38 1235 1155 890
110/43 1105 950 795
1 Based on average ice slab weight of 10.25 - 11.50 lb.
2 230/50/1 is approximately 12% lower than 230/60/1
OPERATING PRESSURES
Air Temp
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
50/10 220-280 40-24 150-180 70-90
70/21 220-280 40-26 160-180 70-90
80/27 240-290 50-27 160-180 70-90
90/32 260-330 50-27 180-200 80-100
100/38 300-370 54-28 200-220 90-115
110/43 330-410 60-29 220-250 100-130
1 Suction pressure drops gradually throughout the freeze cycle