Part Number STH025 11/16 51
Preventative Maintenance Cleaning
Procedure
This procedure cleans all components in the water flow
path, and is used to clean the ice machine between the
bi-yearly cleaning/sanitizing procedure.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
NOTE: Although not required and dependant on your
installation, removing the ice machine top cover may
allow easier access.
1. Ice must not be on the evaporator during the clean/
sanitize cycle. Follow one of the methods below:
Press the power switch at the end of a harvest cycle
after ice falls from the evaporator(s).
Press the power switch and allow the ice to melt.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
2. Open the front door to access the evaporator.