146 Part Number 80-1230-9 10/10
Refrigeration Diagnostics
BEFORE BEGINNING SERVICE
Ice machines may experience operational problems
only during certain times of the day or night. A
machine may function properly while it is being
serviced, but malfunctions later. Information provided
by the user can help the technician start in the right
direction, and may be a determining factor in the final
diagnosis.
Ask these questions before beginning service:
When does the ice machine malfunction? (night,
day, all the time, only during the Freeze cycle, etc.)
When do you notice low ice production? (one day
a week, every day, on weekends, etc.)
Can you describe exactly what the ice machine
seems to be doing?
Has anyone been working on the ice machine?
During “store shutdown,” is the circuit breaker,
water supply or air temperature altered?
Is there any reason why incoming water pressure
might rise or drop substantially?
INSTALLATION/VISUAL INSPECTION CHECKLIST
Possible Problem List Corrective Action List
Filter and/or condenser is
dirty.
Clean the filter and
condenser.
Water filtration is plugged (if
used).
Install a new water filter.
Water drains are not run
separately and/or are not
vented.
Run and vent drains
according to the installation
manual.

Table of Contents

Other manuals for Manitowoc QF0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QF0400 and is the answer not in the manual?

Manitowoc QF0400 Specifications

General IconGeneral
BrandManitowoc
ModelQF0400
CategoryIce Maker
LanguageEnglish

Related product manuals