Part Number 80-1230-9 10/10 231
SUCTION LINE FILTER
Remote condensing units have a suction line filter to
trap particles introduced during field installation. The
suction filter does not have acid or moisture removal
capabilities.
SUCTION CLEANUP FILTER-DRIER
Contaminated systems must have a suction line filter-
drier installed to remove contamination. (See “System
Contamination Cleanup.”) An access valve must be
installed on the inlet side of the suction filter to allow
pressure drop readings to be obtained.
QF2200/RFC2085 and QF2300/RFC2385
Contact your local Manitowoc Distributor for a suction
filter capable of cleaning the system. The clean-up
filter drier must have a minimum nominal capacity of
3 hp. After clean-up is complete (See “System
Contamination Cleanup”), remove clean-up filter drier
and replace with new suction filter.
Model Drier Size
End
Connection
Size
Part
Number
RFC0985
RFC1285
ASF35S5 5/8 in. 82-5053-9
RFC2085R
FC2385
ASF45S6 3/4 in. 82-5026-3
Suction Line Clean-Up Filter
Model Drier Size
End
Connection
Size
SN012/SN020
QF400
SF400/SN450
SF600/SN650
QF800/QC700
SF900/SN950
SF1200/SN1250
UK-165S 5/8 in.

Table of Contents

Other manuals for Manitowoc QF0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QF0400 and is the answer not in the manual?

Manitowoc QF0400 Specifications

General IconGeneral
BrandManitowoc
ModelQF0400
CategoryIce Maker
LanguageEnglish

Related product manuals