Preventative Maintenance Procedure
QF0400
Preventative Maintenance Cleaning Procedure
Step 1 Set the toggle switch to the OFF position.
Open bin door and remove the 2 thumbscrews and
back evaporator panel.
Step 2 To start a cleaning cycle, move the toggle
switch to the CLEAN position. Water will flow through
the water dump valve and down the drain. The flush,
gear motor, speed, dump valve and water solenoid
lights will energize to indicate the ice machine is in the
cleaning mode.
Step 3 Wait about 1 minute or until the dump valve
light de-energizes. Lift the front cover on the reservoir
and add the proper amount of Manitowoc Ice Machine
Cleaner
.
Step 4 The ice machine will automatically time out
four Flush and Rinse cycles, and then stop. The Flush
light remains energized until the toggle switch is
moved to the OFF position. This entire cycle lasts
approximately 11 minutes.
Use Manitowoc clear (P/N 000000084) Ice
Machine Cleaner only. It is a violation of Federal
law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels printed on bottles before
use.
Model
Amount of Cleaner Part
Number 000000084
QF0400 2 oz. (60 ml)