156 Part Number 80-1230-9 10/10
WATER LEVEL CHECK
QF0400/QC0700/QF0800/QF2200/QF2300
The float valve maintains the correct water level. The
water level must allow the water level probes to
maintain water contact throughout the Freeze cycle.
The water level is factory set and normally will not
require adjustment. Check the water level during the
Freeze cycle. The water level is correct if the Water
Level indicator light is energized and no water is
entering the overflow tube. (Check for overflow water
exiting the ice machine drain line at the floor drain.)
If adjustments are necessary:
A. Rotate float clockwise to increase water level.
B. Rotate float counterclockwise to decrease
water level.
Verify the outlet for the water float valve is at a 20° to
30° angle to prevent contact with the float.