66 Part Number 80-1230-9 10/10
QF400
Removal of Parts for Cleaning and Sanitizing
Water Level Probe Removal
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Pull up on water level probes to remove.
4. Disconnect wires from water level probes or
control board.
Water Reservoir Cover Removal
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Remove water level probes.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure
tube.
6. Remove top cover from float reservoir.