52 Part Number 80-1230-9 10/10
Changing toggle switch position during clean
cycle:
1. Less than 60 seconds into Clean cycle - The
Clean cycle will end when the toggle switch is
moved to the OFF position.
2. More than 60 seconds into Clean cycle - The ice
machine will complete the clean cycle. Toggle
switch position will determine the next cycle after
the Clean cycle is completed.
CLEAN POSITION - The ice machine will wait for
a change in toggle switch position.
OFF POSITION - The ice machine will wait for a
change in toggle switch position.
ICE POSITION - The ice machine will start making
ice automatically.
3. To abort the clean cycle move the toggle switch
from CLEAN to OFF to CLEAN and back to OFF
within a 15 second time period.
Manitowoc recommends disassembling, cleaning and
sanitizing the ice machine and dispenser every six
months.