Technical Information
72
G 1xxx/G 2xxx
3.2 Noises during Drying Cycle
Symptom:
After the fan is switched on, there may be noises during the drying cycle.
Cause:
Fan impeller not firmly mounted.
Remedy:
Replace the fan (see Section 040-4.5).
4 Service
4.1 Door Seal Replacement
1. Open the door.
2. Remove the old seal.
3. Clean the groove around the cabinet.
Note:
Coating the seal with water may simplify installation.
4. Press the new seal in the groove; see Figure 040-3, Item 1. The seal lip
should point inwards.
5. Then press the middle of the new seal into the groove under the locking
plate; see Figure 040-3, Item 2. At the same time, press the seal into the
corners.
6. Now press the remaining seal parts into the groove, working upwards in
the direction of the arrows; see Figure 040-3, Item 3.
Figure 040-3: Seal Install Guide