Installation
112
Installation
In order to reduce the risk of possible damage from condensa-
tion, the furniture in the area around the commercial dishwasher
should be designed for commercial use.
The dishwasher must be installed in a secure and level position. Use
the four feet to compensate for any unevenness in the floor and ad-
just the height of the machine.
If the dishwasher is to be installed next to other appliances and furni-
ture or in a recess, an installation space measuring at least 23 5/8"
wide and 23 5/8" deep (60cm by 60cm) is required.
Undercounter in-
stallation
To ensure the stability of undercounter commercial dishwash-
ers, these units may only be installed beneath a continuous coun-
tertop that is bolted to adjacent cabinetry.
If the dishwasher is to be installed beneath a continuous countertop,
an installation space measuring at least 23 5/8" wide, 23 5/8" deep
and 32 1/4" high (60cm wide, 60cm deep, 82cm high) is required.
When adjusting the dishwasher height, the feet may only be
screwed out up to 2 1/4" (6cm).
If the dishwasher is equipped with a cover, it can be removed as fol-
lows:
Remove both securing screws on the back of the dishwasher with a
screwdriver.
Open the door.
Unscrew the left and right fastening screws with a screwdriver.
Lift the appliance cover upwards to remove.