15
Visual Check of Seal Integrity of Mechanical Assembly
Check for leaks in the following components. If leaks exist, contact the factory for assistance.
1. Motor ange: If leaking, replace motor ange sealing gasket (Item 11 in Figure 5-2).
2. Stroke adjustment knob: If leaking, replace stroke adjustment seal (Item 160 in Figure 5-2).
Checking the Pump Capacity
Assuming the pump has been calibrated as described in Section 3, the capacity can be checked by shutting
the valve from the supply vessel and opening the valve from the calibration column to the suction side of the
liquid end. Measure the volume of pumped liquid for a given period of time at the various settings.
If a Calibration column is not installed in the suction piping, place the foot valve (or suction line) in a calibrating
chamber (graduated reservoir). Measure the volume of pumped liquid for a given period of time at the various
settings.
Occurrence of Leak From Detection Ports
Determine whether the product collected at the detection port in the liquid end mounting assembly is
lubricating oil or the pumped uid.
If the product is pumped uid, the diaphragm has failed. If the product is lubricating oil, the oil seal bellows has
failed. Proceed with its replacement (see Section 4.6 Diaphragm and Oil Seal Bellows Replacement).
4.4 SPARE PARTS
The following spare parts should be stocked for each pump to prevent serious delays in repairs.
Parts orders must include the following:
1.Quantity required
2.Part number
3.Part description
4.Pump serial number (found on nameplate)
5.Pump product code (found on nameplate)
Note:
Always include the serial number and product code in all correspondence regarding the unit
4.4.1 GM0002~GM0050 LIQUID ENDS-PVC AND PVDF
1 each, Diaphragm Assembly
1 each, Oil Seal Bellows
1 each, Suc../Dis. Cartridge Valve Assembly
1 each, Foot Valve
1 each, Injection Valve
Note:
Injection valve and foot valve are not available for pump which connection code is “P”.
4.4.2 GM0002~GM0050 LIQUID ENDS-STAINLESS STEEL
1 each, Diaphragm Assembly
1 each, Oil Seal Bellows
2 each, Ball Check D. 9.52

Table of Contents

Other manuals for Milton Roy GM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Milton Roy GM Series and is the answer not in the manual?

Milton Roy GM Series Specifications

General IconGeneral
BrandMilton Roy
ModelGM Series
CategoryWater Pump
LanguageEnglish

Related product manuals