63
S
YSTEM CAPACITY
CHAPTER 3 EXPANSION STAGES AND SYSTEM CAPACITY
Terminals
Expansion key modules on Mitel
6800/6900 SIP phones
200 200
Alpha keyboard Mitel K680 200 200
Alpha keyboard (AKB) 200 200
1. Only 1 operator console, 1 MiVoice 2380 IP, 1 Mitel SIP-DECT, 2 DECT-cordless phones and 1 MiCollab client (3 MiCollab
clients with MiCollab version 8.1) are possible for each user.
2. Audio channels can be used for voice mail, auto attendant, queue with announcement, call recording, announcement with
audio file, or conference bridge. Announcement service and music on hold use their own resources.
3. Of relevance only to certain countries such as Brazil
4. 12 of them are masked (not configurable)
5. In USA/Canada the abbreviation DID (Direct Inward Dial) is used instead of DDI (Direct Dialling In)
6. Only 6 on Mitel 6940 SIP Mitel 6873 SIP if phone is also used as reception phone.
7. Depending on the phone type: Aastra 6730i/31i: 6 keys; Mitel 6735/37/39/53/55/57 SIP: 9 keys; Mitel 6863 SIP: 2 keys;
Mitel 6865/67 SIP: 9 keys; Mitel 6869/73 SIP: 12 keys; Mitel 6900 SIP: 12 keys
8. The value applies to CDE with destination KT line. With MiVoice Office 400 multiple destinations (User + KT or KT + UG) the
value is reduced to 4.
9. Depending on the highest number of line keys, configured for the same line. The following pairs apply (line keys per line /
total line keys): (16/48), (14/56), (12/72), (10/100), (8/160), (6/240), (4/320), (2/400).Example: The following line keys are
configured on different Mitel SIP phones: 8 keys for line 1, 14 keys for line 2, 10 keys for line 3, 10 keys for line 4.
Highest number of keys per line: 14
total 56 line keys are allowed
Configured line keys: 8 + 14 + 10 + 10 = 42 -> OK
10.The call data memory is only used if the output destination is blocked (e.g. printer jam).
11.Limited by the maximum number of terminals (4 interface cards 8DSI required).
Table 3.16:Maximum number of terminals per system and interface (Sheet 1 of 5)
Interface Terminal
type
Terminal SMBC AIN with
SMBC as
Master
per interface
Miscellaneo
us
Terminals (including virtual
terminals and integrated
mobile/external phones)
200 200
Miscellaneo
us
Terminals (excluding virtual
terminals and integrated
mobile/external phones)
200 200
Miscellaneo
us
Free seating pools 200 200
DSI Terminals on DSI interfaces
(total)
64
1
200
Table 3.15:General system capacity (Continued) (Sheet 6 of 6)