Terminal connection diagrams
24
INSTALLATION AND WIRING
2.4 Terminal connection diagrams
FM type
R1/L11
S1/L21
PC
Frequency setting signals (Analog)
10E(+10V)
10(+5V)
2
(Analog common)
2
3
1
Auxiliary
input
Terminal 4 input
(Current input)
1
4
Frequency setting
potentiometer
1/2W1kΩ
Running
Up to frequency
Overload
Frequency detection
Open collector output common
Sink/source common
F/C
(FM)
SD
Relay output 1
(Fault output)
C1
B1
A1
U
V
W
Indicator
(Frequency
meter, etc.)
+-
(-)
(+)
Analog signal output
(0 to ±10VDC)
Earth
(Ground)
AM
5
0 to ±5VDC selectable
0 to ±10VDC
Open collector output 
Moving-coil type
1mA full-scale
Calibration
resistor

Main circuit terminal
Control circuit terminal
0 to 5VDC
0 to 10VDC
C2
B2
A2
Relay output 2
Relay output 
0 to 20mADC
0 to 5VDC
0 to 10VDC
selectable
4 to 20mADC
TXD+
TXD-
RXD+
RXD-
GND
(SG)
Data
transmission
GND
RS-485 terminals
SINK
SOURCE






Connector for plug-in option connection
STF
STR
STP(STOP)
RH
RM
RL
JOG
RT
MRS
X10
RES
AU
CS
SD
RUN
SU
IPF
OL
FU
SE
Data
reception
(+)
(-)
5
VCC
(+)
(-)
5V
Sink logic

N/-
P/+
Initial value
ON
OFF
42
For manufacturer
So (SO)
SOC
Shorting
wire
S1
S2
PC
SD
SIC
+24
SD
Jumper

(Permissible load
current 100mA)
Connector 1 Connector 2
Connector 3
24V external power
supply input
Common terminal
24VDC power supply
(Common for external power supply transistor)
Forward rotation start
Reverse rotation start
Start self-holding selection
Middle speed
High speed
Low speed
Jog operation
Second function selection
Reset
Terminal 4 input selection
Selection of automatic restart
after instantaneous power failure
Control input signals
(No voltage input allowed) 
Multi-speed
selection
Contact input common
Main circuit
Control circuit
PU
connector
USB A
connector
Voltage/current
input switch
selectable
Terminating
resistor
Initial value
Initial value
Output stop
RDA
RDI
Converter
unit
RSO
SE
N/-
P/+
IPF
RDB
FAN
R/L1
S/L2
T/L3
OH
RES
SD
PC
+24
C1
B1
A1


To motor
24V

Table of Contents

Other manuals for Mitsubishi Electric A800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric A800 and is the answer not in the manual?

Mitsubishi Electric A800 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelA800
CategoryInverter
LanguageEnglish

Related product manuals