Page #43 background image
© National Instruments | 2-25
RMC-8357 User Manual
RSC-R2UW-2E8R Slot1 PCI-E x8 (OPROM)/RSC-R2UW-4E8 Slot4 PCI-E x8
(OPROM)/RSC-R2UW-4E8 Slot3 PCI-E x8 (OPROM)/RSC-R2UW-4E8 Slot1
PCI-E x8 (OPROM)/ RSC-R2UW-4E8 Slot2 PCI-E x8 (OPROM)
Select Enabled to enable Option ROM support to boot the computer using a device installed on
the slot specified by the user. The options are Disabled, Legacy, and EFI.
Onboard LAN OPROM
Use this option to select the type of device installed in LAN Port used for system boot.
The default setting for LAN OPROM is EFI.
VGA Priority
Use this item to select the graphics device to be used as the primary video display at bootup.
The options are Onboard and Offboard.
Network Stack
Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unified Extensible
Firmware Interface) for network stack support. The options are Enabled and Disabled.
Ipv6 PXE Support
Select Enabled to enable Ipv6 PXE (Preboot Execution Environment) for boot support. If this
feature is set to Disabled, Ipv6 PXE boot option will not be supported. The options are Enabled
and Disabled.
Note Available when Network Stack is set to Enabled.
Super IO Configuration
Super IO Chip AST2400
Serial Port 1 Configuration/Serial Port 2 Configuration
Select Enabled to enable the onboard serial port specified by the user. The options are Enabled
and Disabled.
Device Settings
This item displays the base I/O port address and the Interrupt Request address of a serial port
specified by the user.
Change Port 1 Settings/Change Port 2 Settings
This feature specifies the base I/O port address and the Interrupt Request address of Serial Port 1
or Serial Port 2. Select Auto for the BIOS to automatically assign the base I/O and IRQ address
to a serial port specified.

Table of Contents

Other manuals for National Instruments RMC-8357

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments RMC-8357 and is the answer not in the manual?

National Instruments RMC-8357 Specifications

General IconGeneral
BrandNational Instruments
ModelRMC-8357
CategoryController
LanguageEnglish

Related product manuals