6-2
6.1.2. Input Signal
Horizontal synchronization frequency: 31 kHz (Negative)
Vertical synchronization frequency: 42Hz (Negative)
6.1.3 Program
Service tool Ver. 4.01 (Part No. 715L2005-C2)
6.1.4 Operation
By taking up the 4.8.1 “Factory mode” procedure, enter into Factory Mode, and then setting “EDID WP” for “OFF”.
6.1.4.1 EDID Data Inspection and Writing to the D-SUB Connector (Analog)
1. Connect the EDID data writing unit with jigs, etc. (Refer to the D-SUB connector connection figure)
2. Select the analog part of EDID, and Start the service tool with fileWinDDC.exe
3. When the screen as shown below appears, click the [W
riteEDID] button