5.2 - Connecting the automation to the mains electricity
WARNING! – The automation must be connected to the mains electricity by an expert and qualied electrician, in accordance
with established laws, standards and local regulations.
Proceed as described below
01. Manually release the gearmotor so that the gate can be opened and closed
02. Move the gate leaf to the halfway position of its path
03. Manually lock the gearmotor
04. Power the automation and verify:
- that the motor is not moving
- that the OK LED (green) ashes regularly at the frequency of one ash per second
- that the warning light connected to the FLASH output is off
ON
FLASH
OFF
2
Flash
8 7 6 5 4 3 2 1
Photo Test
Photo
GND
Stop
SbS
L1
L2
L3
24 V
Aerial
OpenStop/SetClose
if any of these conditions are not satised, proceed as follows (Step 05)
05. Disconnect the automation from the mains power and check the electrical connections, photocell alignment and fuses. Consult Chapter
10 (Troubleshooting) if necessary