English – 21
8 ashes
1-sec pause
8 ashes
Command already present. Another command is already present. Remove the command present to be able to
send other commands.
10 ashes
1-sec pause
10 ashes
Manoeuvre time-out or lack of
motor power during the position
recognition phase
The time-out denotes that the manoeuvre is too long. Shorten the manoeuvre time by
increasing the speed or balancing the gate to reduce the motor’s effort. If the motor
lacks power check whether the board is properly inserted in its housing
9.2 - Signals of LEDs on the control unit
The control unit contains LEDs that can emit
special signals both during normal operation
and in case of anomalies.
L4(R)
L1L2L3
Close
Open
Stop/Set
Flash
Photo
Photo Test
Stop
GND
SbS
24 V
Aerial
L4(R)
L1L2L3
Close
Open
Stop/Set
Fla
sh
Photo
Photo Test
Stop
GND
SbS
24 V
Aerial
9 10
Table 18 - Terminal LEDs (Fig. 9)
OK LED Cause Solution
Red and green LED off Fault Make sure there is power supply; check to see whether the fuses are blown;
if necessary, identify the reason for the failure then replace them with others
of the same type.
Green or red LED on Serious fault Try switching off the control unit for a few seconds; if the condition persists,
it means that there is a malfunction and the electronic circuit board has to
be replaced.
1 green ash per second All OK Normal control unit operation.
2 quick green ashes Input status variation This is normal when there is a change in one of the inputs: SbS, STOP, inter-
vention of photocells or the radio transmitter is used.
Series of red ashes separated
by a 1-second pause
Various Same signal on the warning light or courtesy light: see Table 20
STOP LED (red) Cause Solution
OFF Input intervention
STOP
Check the devices connected to the STOP input
On All OK STOP input active
Table 19 - Button LEDs (Fig. 10)
L1 Description
Off During normal operation it indicates “Short slowdown”
On During normal operation it indicates “Long slowdown”
Flashes Function programming in progress
L2 Description
OFF During normal operation it indicates slow “Motor speed”
On During normal operation it indicates fast “Motor speed”
Flashes - Function programming in progress
- If it ashes together with LEDs L1 and L3, the user must run the recognition phase of the gate opening
and closing positions (Paragraph 7.3).
L3 Description
OFF During normal operation the device indicates “Automatic Closing” is inactive.
On During normal operation the device indicates “Automatic Closing” is active.
Flashes - Function programming in progress
- If it ashes together with LEDs L1 and L2, the user must run the recognition phase of the gate opening
and closing positions (Paragraph 7.3).
L4(R) (radio) Description
On During normal operation it indicates that a radio code not present in the memory has been received.
Flashes Transmitter programming or deletion under way

Table of Contents

Other manuals for Nice RD400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice RD400 and is the answer not in the manual?

Nice RD400 Specifications

General IconGeneral
BrandNice
ModelRD400
CategoryGarage Door Opener
LanguageEnglish

Related product manuals