- A ・ -
Q0340グラフィック用ロゴ
060411デザイン部伊藤
VBA14001-R.3694.A
J0
J
J
(J18037-2)
(J18409)
(J18389)
Device:
1.Main mirror 45° inspection and adjustment
2.Sub-mirror 59° inspection and adjustment
Angle inspection and adjustment of Main mirror and sub-mirror
①
Collimator (J19110)
②
Reection mirror (J18389)
③
Optical parallel (J18037-2)
④
Hexagonal wrench
Main mirror
Eccentric pin for
the main mirror
Collimator
Bayonet
①
Collimator (J19110)
②
59° mirror tool (J18409)
③
Hexagonal wrench
Sub-mirror
Eccentric pin for
the sub-mirror
Collimator
Bayonet
Standard:
Main mirror Sub-mirror
Left-right
deviation
± 25’
__
Up-down
deviation
± 10’
+5 ± 5’
Distortion
8’or less
8’or less
Up-down
Left-right
Reference line
Width of line indicates deviation
Caution:
・
Before and after the adjustment, check the accuracy by moving the main mirror up- and downwards a few
times.
・
Check for the up-down deviation. In case the result is out of standard, make an adjustment by turning the
eccentric pin with Hexagonal wrench.
・
In case the the result of checking up-downward and right-leftward deviation is out of standard, the front plate
area or mirror unit should be defective.
・
In case inspection and adjustment are made only with the front body, check again after assembling the front
body into the rear body.