Installation
A1-8
E 2000 Nordson Corporation
All rights reserved
41-3000V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
1. See Figure A 1-5. Install the air pressure regulator, gauge, and filter
that were shipped with your unit.
4130014A
Fig. A 1 -5 Installing the Air Pressure Regulator, Gauge, and Filter
2. Turn the regulator fully counterclockwise (off).
NOTE: Nordson recommends installing a shutoff valve with a
lock-out in the air supply line to isolate the unit from the air supply for
maintenance procedures.
3. Connect a supply of clean, dry air to the input air fitting or
shutoff valve.
NOTE: To achieve the rated adhesive output of the unit, you must
connect a plant air supply that is capable of providing the maximum
air pressure specified on the unit. The maximum air pressure is
either 483 kPa (70 psi) or 620 kPa (90 psi), depending upon the type
of pump your unit has. To find the maximum air pressure for your
unit, check the air pressure tag, which is located next to the inlet air
port, above the hose connectors.