Table A 1-25 Record of Customized SYSTEM SETTINGS Features
Feature
Default Options Available
(Programming Code)
Revised Setting
Password Enable Off (0) Off (0) or On (1)
System-Ready Time
Delay
18 minutes From 0 to 60 minutes
Overtemperature Setpoint 218 C (425 F) From 52 to 246 C
(From 125 to 475 F)
Celsius/Fahrenheit Fahrenheit Celsius or Fahrenheit
Global Temperature Band
17 _C(30F)
From6to28C
(From 10 to 50 F)
Individual Temperature
Bands
17 _C(30F)
From6to28C
(From 10 to 50 F)
Sequential or
Simultaneous Startup
Sequential (1) Sequential (1) or
Simultaneous (0)
Display Heater
Proportioning
No display (0) No display (0) or
Show display (1)
Warning or Power
Notification
Warning (0) Warning (0) or
Power (1)
Ready or Pump
Notification
Ready (1) Pump (0) or
Ready (1)
Auto-Energize Pump
(piston pump units only)
On (1) On (1) or Off (0)
Auto-Energize Heaters On (1) On (1) or Off (0)
Auto-Energize Pump
Temperature Setting
(piston pump units only)
READY condition (0) READY (0) or
From 1 to 232 C
(From 1 to 450 F)
Auto-Standby T imeout 0 minutes From 0 to 1440 minutes
In Standby Timeout 0 minutes From 0 to 1440 minutes
Auto-Energize Pattern
Control
On (1) On (1) or Off (0)