Installation
A1-57
E 2000 Nordson Corporation
All rights reserved
41-3000V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
To Delete a Standby or Heater Time
Follow this procedure to delete a Standby or Heater time.
1. From the System Setup area, press the Move Up and Move Down
keys until the light next to the feature you wish to change turns on.
NOTE: If you have enabled the password feature, you must change
the number in the Multipurpose display (500) to the password (321)
and press the Enter key before the system will allow you to change
the clock settings.
2. Check the Selector display. The display flashes the day code
representing a day of the week.
3. Refer to Table A 1-16, and press the Up key below the Selector
display until the day code of the day that you want to change appears
in the Selector display.
4. Press the Enter key to save the setting. The Selector display stops
flashing and the hour shown in the Multipurpose display flashes.
5. Press the Up or Down keys below the Multipurpose display until four
dashes(––––)appear on the display. (The dashes indicate that no
setting has been entered.)
6. Press the Enter key to save the setting. All displays stop flashing.
7. Record your setting in the forms provided at the end of this section.
Refer to Records of System Settings.
To Delete Times for an Entire Day
To delete times for an entire day, follow the procedure To Delete a
Standby or Heater Time and turn the clock off for each feature: entering
standby, exiting standby, turning heaters on, turning heaters off.