G10 Extra Length Delay
when the photocell no
longer detects the
pallet to when the
carriage stops. (sec)
0.0 0.0 10.0 10.0 1.0 1.0 1.0
G11 Brake Calibration
corresponding to
100% of the braking.
This value sets the
maximum percentage,
to which the
percentages of the
other film tension
parameters refer to.
0 0 100 100 15 10 15
G12 Film Tension Start
Film tension, when a
cycle is started and
upon restart from the
pause of the Stretch
Sheet cycle. (in %)
0 0 100 100 10 10 10
G13 Start Delay Time
when the parameter
“Start Film Tension” is
enabled to when the
cycle parameter
“Stretch” (in sec) is
automatically enabled.
0.0 0.0 10.0 10.0 5,0 5,0 5,0
G14
Last Revolution
Tension
the table braking
stage. (in %)
0 0 100 100 15 15 15
G15 Tension Pause
machine is in the
AUTOMATIC mode
and is not performing
0 0 100 100 0 0 0
G16 Descent Time
when the carriage
arrives at the end of
the pallet (for the first
time) to then go down
for this amount of
time. (in sec).
Used only in the
“Stretch Sheet cycle”
0.0 0.0 10.0 10.0 3,0 3,0 3,0
G17 Reset Speed
of the table during the
stage, in which the
table places itself on
zero. (RPM)
1 1 10 10 5 5 5