EasyManuals Logo
Home>Omron>Robotics>Regular Payload

Omron Regular Payload User Manual

Omron Regular Payload
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Regular Payload Series-Hardware Installation Manual TM5 Series Hardware Version: 3.2 50
Figure 41: The Wiring Diagram Example of PNP Output Type Safety Device
5.3.1.2 Safety Output Connector
1. Robot ESTOP Output Port. When the robot triggers the Robot (stick) Emergency Stop signal, the
output will be LOW.
2. User Connected External Safeguard Output Port. When the robot triggers the User Connected
External Safeguard Input, the output will be LOW.
3. User Connected External Safeguard Output Port for HumanMachine Safety Settings. When the
robot triggers the User Connected External Safeguard Input for HumanMachine Safety Settings,
the output will be LOW.
4. Robot Internal Protective Stop Output Port. When the robot triggers the internal Protective Stop,
the output will be LOW.
5. Robot Encoder Standstill Output Port. When the Encoder Standstill is not monitoring (robot is
moving), the output will be LOW.
For details about the safety functions, please refer to the Safety Manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Regular Payload and is the answer not in the manual?

Omron Regular Payload Specifications

General IconGeneral
BrandOmron
ModelRegular Payload
CategoryRobotics
LanguageEnglish

Related product manuals