5 Setup and Wiring
5 - 32
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
Ground
When the connected camera to the Sensor Control comes packaged with a base, make sure to
mount with the base.
Since the enclosure of the camera main body made of me
tals is short-circuited with the internal
circuit, the internal circuit might be short-circuited with FG if no base is used, so that failures or
malfunctions may be caused.
Connect the FH-1000/FH-3000 series Sensor Controller to the FH-SC12 / FH-SN12:
12 megapixels camera
When you connect FH-L series to the FH-SC12 or FH-SM12:
Do not ground the positive terminal of DC24V power
source. The internal circuit is possible to
be given damage, it can be cause the failure.
Secure the minimum bending radius of the cable or cable connector.
When the connected camera to the Sensor Control comes packaged with a base, make sure to
mount with the base.
Since the enclosure of the camera main body made of me
tals is short-circuited with the internal
circuit, the internal circuit might be short-circuited with FG if no base is used, so that failures or
malfunctions may be caused.
5-5-3 FH-L Series
Camera cable mounting
5-5-4 FZ5 Series
Minimum
bending radius
Connector length
Name Model
Minimum
bending
radius
Connector
length
Camera Cable FZ-VS3 69 mm 30 mm
Right-angle Camera Cable FZ-VSL3
Bend resistant Camera Cable FZ-VSB3
Bend resistant Right-angle
Camera Cable
FZ-VSLB3
Long-distance Camera Cable FZ-VS4 78 mm 42 mm
Long-distance Right-angle
Camera Cable
FZ-VSL4