6 I/O Interface
6 - 58
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
RS-232C interface is used in FH-1000, FH-3000, and FH-L series.
Prepare the suitable connector. Recommended connector is the following table.
D-Sub9 Male type connector is used in Sensor Controller.
Bundle each cable with SG (signal ground) as a twiste
d pair cable. Connect the bundled SG cables
with the connector on the Sensor Controller and the connector on the other device.
Connect the communication cable shield to the RS-232C connector shell (FG) on the Sensor Con-
troller.
The pin numbering will differ depending on
type and model of the connected external device.
6-5-2 FH-1000, FH-3000, and FH-L Series
Input and output Connector
Manufacturer Model
Sockets OMRON Corporation XM3D-0921
Hood OMRON Corporation XM2S-0911
Pin Layout
Pin No. Signal name Function
1 NC Not connected
2 RD Data reception
3 SD Data transmission
4 NC Not connected
5 GND Signal ground
6 NC Not connected
7 NC Not connected
8 NC Not connected
9 NC Not connected
Wiring
5
4
3
2
1
9
8
7
6
Signal name
RD
SD
GND
Sensor Controller
Pin No.
2
3
5
Pin No.
External device to be connected
RS/CS control cannot be used
Signal name
RD*
*
*
SD
GND
Use a shielded cable.

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals