6 - 47
6 I/O Interface
Vision System FH/FZ5 series Hardware Setup Manual (Z366)
6-3 EtherCAT Interface
6
6-3 EtherCAT Interface
EtherCAT interface is supported only FH-1000, FH-3000 series.
Precautions for Safe Use
Use only the cables designed specifically for the product. Use of other products may result in
malfunction or damage of the product.
Always turn OFF the FH Sensor Controller's power before connecting or disconnecting a
camera or cable. Connecting the cable with power supplied may result in damage of the
camera or peripheral devices.
For the cable that is flexed repeatedly, use th
e robotic cable type (Bend resistant camera
cable) to prevent damages.
Do not apply torsion stress to the cable. It may damage the cable.
Secure the minimum bending radius of the ca
ble. Otherwise the cable may be damaged.
Precautions for Correct Use
Check the following items on the communications cables that are used in the network.
Are there any breaks?
Are there any shorts?
Are there any connector problems?
When you connect the cable to the communications co
nnectors on devices, firmly insert the
communications cable connector until it locks in place.
Do not lay the communications cables together with high-voltage lines.
Do not lay the communications cable near devices that generate noise.
Do not lay the communications ca
bles in locations subject to high temperatures or high
humidity.
Do not lay the communications cables in lo
cations subject to excessive dirt and dust or to oil
mist or other contaminants.
Connect a straight LAN cable.
Use an STP cable of category 5e or higher, which is shielded double with an aluminum tape and a
braided cord.
The cable is maximum 100 m long. However, some cable
s do not guarantee 100 m. If conductor
is a twisted cable, transmission performance generally becomes worse than that of straight
cables, so that 100 m cannot be guaranteed. For details, contact the cable manufacturer.
Electrical specifications: Conforming
to IEEE 802.3 standards. Use RJ45 8-pin Modular Connec-
tor (conforming to ISO 8877),
When selecting a connector, confirm that
it is applicable to the cable that will be used. Confirm the
following items: Conductor size, conductor type (solid wire or twisted wire), number of twisted
pairs (2 or 4), outer diameter, etc.
Cable
I/O Connector

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals