Regulations and standards
−41−
13 Regulations and standards
13.1 UL Standards, CSA Standards
This product is recognized by UL under the UL and CSA Standards.
13.2 CE Marking/UKCA Marking
This product is axed with the marks under the following directives/regulations.
EU Low Voltage Directive/UK Electrical Equipment (Safety) Regulation
Installation conditions
Overvoltage category
Ⅱ
Pollution degree 2
Degree of protection IP20
Protection against electric shock Class
Ⅰ
equipment
z
This product cannot be used in IT power distribution systems.
z
Isolate the cable for connecting between the motor and the driver, the power supply cable and other drive
cables from the signal cables (CN4) by means of double insulation.
z
Use a circuit breaker conforming to EN or IEC Standards.
z
The driver is not provided with the motor overtemperature protection specied in EN Standards.
z
The driver is provided with the electronic motor overload protection specied in EN Standards.
Overload protection characteristics
200
100
Overload protection
activation line
Operating time
T = Overload protection activation operating time 0.1 to 60.0 s
The driver is provided with the electronic motor overload protection, but is not provided with the thermal
memory retention function and the speed sensitive function.