Operating
−21−
7.3 Operating by programmable controller
Moto
river
AC power
supply
Programmable
The motor can be operated and stopped externally.
When the motor is operated and stopped externally, the "external operation signal input" parameter ( )
is required to change.
Operating
After connecting the operation input signals (FWD input, REV input) to the CN4, set and operate the product
as follows.
1
2
3
4
5
Setting the "external operation signal input" parameter
Change the "external operation signal input" parameter to the
external operation.
Turn the FWD input or the REV input ON.
If the operation input signal being ON is
turned OFF
Power ON
Operation signals
Motor rotates
Motor deceleration stops
[ Connecting to the CN4 ]
• When using a programmable
controller
•
When using switches and relays
Operation
This operation example is for when the rotation speed is set to the operation data No.0.
Setting the "external operation signal input" parameter
Change the setting for the "external operation signal input" parameter ( ) when operating and stopping the motor
externally.
•
"OFF" at the time of shipment: The operation using the front panel is set.
•
Change to "ON" or "rE" for the setting of external operation.
Setting range
: Operation/standstill using front panel (Factory setting)
: Operation/standstill using external signals (The operation with the front panel is Enabled.)
: Operation/standstill using external signals (The operation with the front panel is Disabled.)
The "external operation signal input" parameter ( ) is found in the parameter mode. (p.26)
Front panel operation
Operation using the switches and setting dial on the front panel can be set to " Enable:
○
" or " Disable:
×
."
Setting Operation switch Rotation direction switch Setting dial
Operation switch
Rotation direct
switch
Setting dial
○ ○ ○
× ×
× *
*
The data mode, parameter mode, and the I/O monitor of the monitor mode
are enabled (possible to set).
Connection: p.14
p.18
p.16