1.7 Extension Settings
82 User Manual
1.7.4 Calling Line Identification Presentation (CLIP)
CLIP:
When making an outside call, you can present your preprogrammed telephone number to the called party.
You can select the telephone number sent, either the number of the line used or the number assigned to
your extension.
If you select "Public", the calling/called party sees the number of the line used (subscriber's number).
If you select "Your extension", they see the telephone number assigned on your extension.
To show either the number assigned to the CO line or your extension
1.7.5 Calling Line Identification Restriction (CLIR)
When making an outside call, you can select whether the called party can see your telephone number or
not.
To show/prevent
If you use the G-DN button to make a call to the other party, the telephone number assigned
to the G-DN will be used.
You can change the mode by pressing a preset CLIR button while on-hook.
The CLIR button light shows the current status as follows:
Off: shows your telephone number.
Red on: prevents your telephone number being displayed.
Availability of this feature depends on the ISDN service of your telephone company.
Customizing Your Phone
3.1.3 Customizing the Buttons
Create or edit a Calling Line Identification Restriction (CLIR) button.
Off-hook.
On-hook.
Enter
1
for public or
2
for your extension.
PT/SLT/PS
Public
Your extension
OR
1
2
Enter
7 2
.
27
C.Tone
On-hook.Off-hook.
PT/SLT/PS
Enter
7 1
.
Show
Prevent
0
1
OR
17
Enter
0
to show
or
1
to prevent.
C.Tone

Table of Contents

Other manuals for Panasonic KX-TDA100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-TDA100 and is the answer not in the manual?

Panasonic KX-TDA100 Specifications

General IconGeneral
System CapacityUp to 128 extensions
VoIP SupportYes, with optional cards
Digital ExtensionsYes
Analog ExtensionsYes
ISDN SupportYes
Power SupplyAC 100-240 V, 50/60 Hz
Operating Temperature0°C to 40°C
Humidity10% to 90% (non-condensing)
NetworkingYes
TypeHybrid IP PBX
Wireless CapabilityYes
Supported ExtensionsDigital, Analog
Trunk InterfacesAnalog, ISDN
Voicemail CapacityOptional, via voice processing cards

Related product manuals