10 R eference & Installation Manual
4.0 System Options
4.1 Partit ion Assignment
SECTION [001]: O PT IONS [1] TO [8]
Each keypad in the system can be assigned to one or more
partit ions. In s ec tion [001], options [1] to [8] represent partitions
1 through 8 respectively. To assign the keypad to a partition,
simply enable the option that corresponds to the desired
partition. By default, partitions 1 to 8 are enabled.
Section [001] op tions [5] to [8] can only be used if the
keypad is connected to a DigiplexNE (DGP-NE96)
control pan el.
4.2 Display Acces s Code Entry
SECTION [003]: O PT ION [1]
The digits of the User Access Codes can be displayed on the
LCD screen when they are entered.
4.3 Display Exit Delay Timer
SECTION [003]: O PT ION [2]
Based on the user's needs, an Exit Delay Timer will be
programmed to provide the user time to exit the partition before
the system is armed. The Exit Delay Timer's countdown can be
displayed on the LCD screen.
O
ption [1] OFF = Digits are replaced by a * (default).
Option [1] ON = Access Code digits will be displayed.