12 R eference & Installation Manual
Mode will appear and display the date and time as shown in
Figure 4.1 on page 12. The status of the areas, the open zones
for every area the keypad is assigned, the Alarm Memory
Display (if necessary) and the Trouble Display (if necessary. See
Digiplex or DigiplexNE User Manual) will also scroll on the LCD
screen.
Figure 4.1: LCD Screen
4.6 Confidential Mode Timer
SECTION [007]
Section [007] determines the amount of time without action
before the keypad enters Confidential Mode. For more
information on Confidential Mode, refer to “Confidential Mode” on
page 11. The Confidential Mode Timer can be set from 005
seconds to 255 seconds. Default: 120 seconds.
Option [4] OFF = Normal Mode (default).
Option [4] ON = Confidential Mode.
Option [5] OFF = LCD screen activated by entering an access
code (default).
Option [5] ON = LCD screen activated by pressing a button