Digiplex/DigiplexNE LCD Keypad 17n
5.0 Programmable Output Options
5.1 PGM State
SECTION [006]: O PT ION [1]
The keypad's on-board PGM can be set as normally open or
normally closed. When an open PGM is activated, it will close the
circuit from ground and enable any devices connected to it.
When a c losed PGM is activated, it will open the circuit and
disable any devices connected to it. When the PGM Activation
Ev ent occurs (see section 5.6), the PGM will switch to its
opposite state (i.e. open to closed or closed to open).
The PGM can provide 50mA to any device connected to
it.
5.2 PGM De activa tion Mode
SECTION [006]: O PT ION [2]
If the keypad is in PGM Timed Mode, the keypad's on-board
PGM will be deactivated according to the PGM Timer (see
section 5.5 below) instead of the PGM Deactivation Event.
Option [1] OFF= PGM is Normally Open (default).
Option [1] ON= PGM is Normally C losed.
Option [2] O FF = D eact iv at e s o n P GM De ac tiva tio n Ev en t
(default).
Option [2] ON = PGM will deactivate according to the PGM
Timer.