DB Series Nitrogen Generator DB5-20 Model
7. Service & Preventative Maintenance
7.1 Service Intervals
DB Series Nitrogen generators are equipped with an hour meter, which is activated when the system is
running. The hour meter is to be used as a guide for sustaining service intervals. If service intervals are
stated in both months & hours, the system should be serviced based on whichever comes first.
Component Operation Daily Weekly Monthly
6
Months
12
Months
60
Months
Filter Drains
Check for proper
drain operation
Switching
Valves
Check condition.
Rebuild and replace
wear parts as needed.
Pilot Valves
Check condition. Rebuild
and replace wear parts
as needed.
Complete
Assembly
Check for air leaks
(when installed and
during operation).
Pre/After
Filters
Replace filter elements
Oxygen
Sensor
Replace oxygen sensor
Check
Serivce
Only competent personnel trained, qualified, and approved by Parker should perform
installation, commissioning, service, and repair procedures.
WARNING