DB Series Nitrogen Generator DB5-20 Model
GN UC H
Product
Code: 28010
Safety Data Sheet
10/20/2020
GN UC H
Product Code: 28010
For Internal Use Only: PR #1
2/7
First-aid measures after ingestion
:
IF SWALLOWED: Rinse mouth thoroughly. Do not induce vomiting without advice from poison
control
center or medical professional. Get medical attention if you feel unwell.
4.2. Most important symptoms and effects, both acute and delayed
Symptoms/injuries after inhalation
:
Not expected to present a significant hazard under anticipated conditions of normal use. Dust
may cause ir
ritation to the respiratory system.
Symptoms/injuries after skin contact
:
Dust may cause irritation.
Symptoms/injuries after eye contact
:
Dust may cause irritation and redness.
Symptoms/injuries after ingestion
:
Not expected to present a significant hazard under anticipated conditions of normal use.
4.3. Indication of any immediate medical attention and special treatment needed
No additional information available.
SECTION 5: Firefighting Measures
5.1. Extinguishing media
Suitable extinguishing media
:
Water spray. Carbon dioxide. Dry chemical. Foam. Sand.
Unsuitable extinguishing media
:
None known.
5.2. Special hazards arising from the substance or mixture
Fire hazard
:
Dust may be combustible under specific conditions. May be ignited by heat, sparks or flames.
Explosion hazard
:
Dust may form explosive mixture in air.
Reactivity
:
No dangerous reactions known under normal conditions of use. Carbon oxides may be emitted
upon combustion of material.
5.3. Advice for firefighters
Firefighting instructions
:
Wear NIOSH-approved self-contained breathing apparatus suitable for the surrounding fire.
Use water spray or fog for cooling exposed containers. Evacuate area.
SECTION 6: Accidental Release Measures
6.1. Personal precautions, protective equipment and emergency procedures
General measures
:
Evacuate area. Keep upwind. Ventilate area. Spill should be handled by trained clean-up crews
properly equipped with respiratory equipment and full chemical protective gear (see
Section 8).
6.1.1. For non-emergency personnel
No additional information available.
6.1.2. For emergency responders
No additional information available.
6.2. Environmental precautions
Prevent entry to sewers and public waters. Avoid release to the environment. Product is not soluble, but can cause particulate emission if
discharged into waterways. Dike all entrances to sewers and drains to avoid introducing material to waterways. Notify authorities if product enters
sewers or public waters.
6.3. Methods and material for containment and cleaning up
For containment
:
Sweep or shovel spills into appropriate container for disposal. Minimize generation of dust.
Methods for cleaning up
:
Sweep or shovel spills into appropriate container for disposal. Minimize generation of dust.
Dispose
of material in compliance with local, state, and federal regulations.
6.4. Reference to other sections
No additional information available.
SECTION 7: Handling and Storage
7.1. Precautions for safe handling
Precautions for safe handling
:
Avoid dust formation. Avoid contact with skin, eyes and clothing. Do not handle until all safety
precautions have been read and understood. Wash hands and other exposed areas with mild
soap and water before eating, drinking or smoking and wh
en leaving work. Keep away from
sour
ces of ignition - No smoking.
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions
:
Keep container tightly closed in a cool, dry, and well-ventilated place. Keep away from ignition
sour
ces.