4.1 FAULT CODE DESCRIPTIONS
SQF-001 SQF-M1 Transport belt motor Short circuit .............................................SQF-4-2
SQF-002 SQF-M1 Transport belt motor Open circuit..............................................SQF-4-2
SQF-003 SQF-M2 Stop
gate motor No displacement pulses .................................SQF-4-2
SQF-004 SQF-M2 Stop
gate motor Short circuit .....................................................SQF-4-3
SQF-005 SQF-M2 Stop
gate motor Open circuit .....................................................SQF-4-3
SQF-006 SQF-M2 Stop
gate motor Cycle time out..................................................SQF-4-3
SQF-007 SQF-M3 Clamp
motor Short circuit ..........................................................SQF-4-4
SQF-008 SQF-M3 Clamp motor Open circuit...........................................................SQF-4-4
SQF-009 SQF-M3 Clamp
motor Cycle time out .......................................................SQF-4-4
SQF-010 SQF-M4 Roller
motor Short circuit ...........................................................SQF-4-5
SQF-011 SQF-M4 Roller
motor Open circuit ...........................................................SQF-4-5
SQF-012 SQF-M4 Roller motor Cycle time out ........................................................SQF-4-6
SQF-013 SQF-M4 Roller
motor No displacement pulses .......................................SQF-4-7
SQF-014 SQF-Q5 Infeed sensor is Faulty ................................................................SQF-4-7
SQF-015 SQF-Q6 Clamp
sensor is Faulty ...............................................................SQF-4-8
SQF-016 SQF-Q7 Outfeed sensor is Faulty .............................................................SQF-4-8
SQF-150 36V input low................................................................................SQF-4-9
SQF-151 36V
input high ..............................................................................SQF-4-9
SQF-152 SQF-SW1,
2, 3
or 4 Interlock switch Squarefolder is Faulty .....................................SQF-4-9
SQF-201 SQF-Q5 Infeed sensor was Not blocked within timeout.......................SQF-4-10
SQF-202 SQF-Q5 Infeed sensor was Blocked exceeding timeout ......................SQF-4-10
SQF-203 SQF-Q6 Clamp sensor was Not blocked within timeout ......................SQF-4-10
SQF-204 SQF-Q6 Clamp sensor was Blocked exceeding timeout......................SQF-4-11
SQF-206 SQF-Q7 Outfeed sensor was Not Blocked exceeding timeout ............SQF-4-11
FAULT CODE DESCRIPTION
CAUTION
ESD Hazard! ESD (Electrostatic Discharge) can cause software crashes,
data and/or communications problems. Failure to use proper ESD pro-
cedures will cause damage to electronic components (example: PCBs).
ESD problems can be minimized by maintaining all machine ground con-
nections, ensuring the proper handling of circuit boards and sensors. Use
ESD protection when working near PCBs. Failure to use ESD protection is
likely to result in a PCB failure ( Service Manual BM 200 3.1 ).