Matrix User Guide
RINS915-2 Page: 19
First To Alarm (FTA) Mode
The first zone to activate an alarm will be shown on the display.
ALARM
ZONE 1
To clear the display and returned to disarmed mode enter the user code again.
If the keypad goes into Hidden Display mode whilst you are in FTA mode, enter your user code again to re-
display the FTA messages.
4.2.4 Latched Alarm Indication – Denmark, Norway, Finland & Sweden only – Single
Partition
A special indication will appear on the LCD display after any valid alarm has been successfully disarmed. The
LCD keypad will display VIEW THE LOG. Whilst this display is active, the keypad will not enter hidden display mode
(if hidden display mode is enabled).
This is to prompt you to check the event log. To remove the latched alarm you must use the user function View
Log described on page 27. Alternatively, enter a valid user code to re-arm the panel. Once armed, the previous
latched alarm will be cleared.
4.2.5 Anti-Code Reset – Single Partition User
If your system has anti code reset enabled, the LCD display will show ‘RESET REQUIRED’.
You will be unable to re-arm your alarm panel until an anti-code number has been entered. Press the C key to
display the anti code seed number. This number should be passed onto your central monitoring station, who will
in turn provide you with a corresponding anti code number.
Enter this anti code number on your keypad (after pressing the C key).
Your system will return to normal operation.
If the keypad drops into hidden display mode, re-enter your user code to unhide the display and press the C
key to re-display the anti-code seed number.
4.2.6 Arming – Multiple Partition User
If all zones are closed the OK LED will be illuminated.
Otherwise use the
&
buttons to list the open zones.
The open zones will be displayed in order on the display:
Enter you personal user code
to arm the panel.
Select the partition(s) to be armed by entering the appropriate numeric button on the keypad: , , or
.
The LCD display will indicate the partitions to arm with an “%” symbol
Alternate presses of the same numeric key will turn the corresponding symbol on / off.
Select all partitions needed to arm and then press to confirm.
Arming will be confirmed by a repeated high tone emitted from the keypad.
Armed partitions are identified by a “&” symbol.