5.4 Arm with Omits
This function allows you to omit any zone(s) before arming the panel.
Icon Keypad LCD Keypad
1. Enter user mode
2. Enter T
Two underscores will appear on the icon display
prompting you to enter a two digit zone number.
For single digit zone numbers ( 1-9 ), type the
zone number preceded by a ‘0’.
If you want to change the zone number you just
typed in, simply type a new two digit zone
number.
3. Press the key to add this zone to the list of
zones to omit. If you have access to that zone
then an acceptance tone will sound. If you do
not have access to that zone a low error tone
will sound indicating that the zone was not
added to the zones to omit list.
4. Repeat this operation for any more zones that
you want to omit.
5. If you decide not to arm with the omitted zones,
press the key again. A low error tone will be
played. This indicates that all omitted zones
have been removed from the omit zone list. The
function will terminate.
6. If you are ready to arm the panel with the
omitted zones, press the C key followed by A,
B, C or D to choose an arm mode.
7. The panel will commence arming as normal
with all selected zones omitted. The armed icon
(í) will flash whilst arming to indicate that one
or more zones are omitted.
Use the and keys to navigate to “ARM WITH
OMITS”, press to select the function. The following
display will be shown:
Use the and keys to scroll through all the
available zones, or enter the two-digit zone number
on the keypad.
To omit the zone press key.
If you wish to leave the `Arm with omits’ option
without arming press the key twice.
To omit all selected zones and arm, press the
key.
Enter
or
to select the Arm mode.
A single partition keypad will start arming in the arm
mode chosen as in the example below (mode B).
A multiple partition keypad will ask for a partition
number to arm. Select the partition and press to
confirm.
Upon arming, the omit indicator is removed.